In this study, Fe and Co tablet samples, which show ferromagnetic properties at room temperature, were magnetised for 300 seconds in a 1T (10 kG) of size magnetic field, which had 12.94 mm distance between its poles. The magnetic field applied on the ferromagnetic samples were measured as F. W. Bell Gauss/Teslameter (Model 5080) and 1 tesla (10 kG) when the distance between its poles were 12.94 mm. Then, the change emerged in the σ Kα and σ Kβ cross sections of Fe and Co were respectively measured as 20º, 40º, 60º, 80º, 100º, 120º and 140º release angles in order. The samples were alerted with KX-rays of silver alerted from Cd-109 radioisotope source of 40 mCi. During the study, an HPGe detector, which has the beryllium window with 25µm diameter and with (FWHM) 210 eV full width at half maximum in 5.9 keV was used. The crystal thickness of this detector was 10 mm and its active field was 200 mm2 , the voltage to be used on the detector was applied till -1500 V at maximum and the shaping time were set as 10µs. The liquid, which is located in a crystal counter and FET were hold in a 30 liters of a liquid nitrogen container (dewar) was kept under nitrogen boiling temperature. The results showed that specifically the magnetization of Fe increased its KX-ray fluorescence cross sections and the fluorescence cross sections of KX-ray fluorescence cross sections for Fe without magnetization were anisotropic although it was not encountered with any anisotropy of magnetized Fe X-rays. Consequently, this was an expected situation as the magnetised Fe and the anisotropy of Co in the σ Kα and σ Kβ values were orientations of ions generated after alerted with photon, which was the anisotropy source of X-rays. However, to make the results more useful, it is necessary to make more studies that are experimental and support these results with studies determining the orientations of atoms in magnetized samples.
Angular Distribution, Magnetization, Cross Section, XRF, X-Rays
Konular
Diğer ID JA36ZP44CY
Dergi Bölümü Makaleler
Yazarlar

Yazar: Paşa YALÇIN

Yazar: Mehmet TERZİ

Yazar: Ali GÜROL

Bibtex @ { else313715, journal = {Electronic Letters on Science\&Engineering}, issn = {1305-8614}, address = {Bozok Üniversitesi}, year = {2016}, volume = {12}, pages = {17 - 18}, doi = {}, title = {THE EFFECT OF MAGNETIZATION ON X- RAY FLUORESCENCE CROSS SECTIONS}, key = {cite}, author = {YALÇIN, Paşa and TERZİ, Mehmet and GÜROL, Ali} }
APA YALÇIN, P , TERZİ, M , GÜROL, A . (2016). THE EFFECT OF MAGNETIZATION ON X- RAY FLUORESCENCE CROSS SECTIONS. Electronic Letters on Science&Engineering, 12 (2), 17-18. Retrieved from http://dergipark.gov.tr/else/issue/29303/313715
MLA YALÇIN, P , TERZİ, M , GÜROL, A . "THE EFFECT OF MAGNETIZATION ON X- RAY FLUORESCENCE CROSS SECTIONS". Electronic Letters on Science&Engineering 12 (2016): 17-18 <http://dergipark.gov.tr/else/issue/29303/313715>
Chicago YALÇIN, P , TERZİ, M , GÜROL, A . "THE EFFECT OF MAGNETIZATION ON X- RAY FLUORESCENCE CROSS SECTIONS". Electronic Letters on Science&Engineering 12 (2016): 17-18
RIS TY - JOUR T1 - THE EFFECT OF MAGNETIZATION ON X- RAY FLUORESCENCE CROSS SECTIONS AU - Paşa YALÇIN , Mehmet TERZİ , Ali GÜROL Y1 - 2016 PY - 2016 N1 - DO - T2 - Electronic Letters on Science&Engineering JF - Journal JO - JOR SP - 17 EP - 18 VL - 12 IS - 2 SN - 1305-8614- M3 - UR - Y2 - 2018 ER -
EndNote %0 Electronic Letters on Science&Engineering THE EFFECT OF MAGNETIZATION ON X- RAY FLUORESCENCE CROSS SECTIONS %A Paşa YALÇIN , Mehmet TERZİ , Ali GÜROL %T THE EFFECT OF MAGNETIZATION ON X- RAY FLUORESCENCE CROSS SECTIONS %D 2016 %J Electronic Letters on Science&Engineering %P 1305-8614- %V 12 %N 2 %R %U