Yıl 2019, Cilt 5, Sayı 2, Sayfalar 407 - 409 2019-03-04

A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation

Deepak Agarwal [1] , Aman Makhija [2] , Arun Mohanty [3] , Raja Ram Mantri [4]

48 178

During cardiac resynchronization therapy implantation, left ventricular lead placement involves transvenous placement of leads via the coronary sinus and into a tributary branch. At present, the most widely used method for left ventricular (LV) lead placement involves a transvenous LV lead placement via the coronary sinus into a tributary branch. Lead dislodgement is a common cause for reoperation. We describe a case where a coronary stent was placed to stabilize the lead against the vessel wall. 

Lead dislodgement, CRT, lead stabilization, coronary sinus, dyssynchrony
  • [1] Bulava A, Lukl J. Single-centre experiencewith coronary sinus lead stability and long-term pacing parameters. Europace 2007;9:523-7.
  • [2] Fujii S, Tasaka H, Kawakami T, Mitsudo K, Takenada S. Stent placement to stabilize the left ventricularlead in the coronary sinus. J Arrhythm 2008;24:162-5.
  • [3] Cesario DA, Shenoda M, Brar R, Shivkumar K. Left ventricular lead stabilization utilizing a coronary stent. Pacing Clin Electrophysiol 2006;29:427-8.
  • [4] Szilagyi S, Merkely B, Roka A, Zima E, Fulop G, Kutyifa V, et al. Stabilization of the coronary sinus electrode position with coronary stent implantation to prevent and treat dislocation. J Cardiovasc Electrophysiol 2007;18:303-7.
  • [5] Biffi M, Bertini M, Ziacchi M, Diemberger I, Martignani C, Boriani G. Left ventricular lead stabilization to retain cardiac resynchronization therapy at long term: when is it advisable? Europace 2014;16:533-40.
Birincil Dil en
Konular Sağlık Bilimleri ve Hizmetleri
Dergi Bölümü Case Report
Yazarlar

Orcid: 0000-0002-5354-2706
Yazar: Deepak Agarwal
Kurum: Department of Cardiology, Sir Ganga Ram Hospital, New Delhi, India
Ülke: India


Orcid: 0000-0002-5704-566X
Yazar: Aman Makhija (Sorumlu Yazar)
Kurum: Department of Cardiology, Sir Ganga Ram Hospital, New Delhi, India
Ülke: India


Orcid: 0000-0002-3736-1809
Yazar: Arun Mohanty
Kurum: Department of Cardiology, Sir Ganga Ram Hospital, New Delhi, India
Ülke: India


Orcid: 0000-0003-0310-1299
Yazar: Raja Ram Mantri
Kurum: Department of Cardiology, Sir Ganga Ram Hospital, New Delhi, India
Ülke: India


Bibtex @olgu sunumu { eurj397159, journal = {The European Research Journal}, issn = {}, eissn = {2149-3189}, address = {Sağlık Araştırmaları ve Stratejileri Derneği}, year = {2019}, volume = {5}, pages = {407 - 409}, doi = {10.18621/eurj.397159}, title = {A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation}, key = {cite}, author = {Agarwal, Deepak and Makhija, Aman and Mohanty, Arun and Mantri, Raja Ram} }
APA Agarwal, D , Makhija, A , Mohanty, A , Mantri, R . (2019). A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation. The European Research Journal, 5 (2), 407-409. DOI: 10.18621/eurj.397159
MLA Agarwal, D , Makhija, A , Mohanty, A , Mantri, R . "A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation". The European Research Journal 5 (2019): 407-409 <http://dergipark.gov.tr/eurj/issue/41339/397159>
Chicago Agarwal, D , Makhija, A , Mohanty, A , Mantri, R . "A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation". The European Research Journal 5 (2019): 407-409
RIS TY - JOUR T1 - A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation AU - Deepak Agarwal , Aman Makhija , Arun Mohanty , Raja Ram Mantri Y1 - 2019 PY - 2019 N1 - doi: 10.18621/eurj.397159 DO - 10.18621/eurj.397159 T2 - The European Research Journal JF - Journal JO - JOR SP - 407 EP - 409 VL - 5 IS - 2 SN - -2149-3189 M3 - doi: 10.18621/eurj.397159 UR - http://dx.doi.org/10.18621/eurj.397159 Y2 - 2018 ER -
EndNote %0 The European Research Journal A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation %A Deepak Agarwal , Aman Makhija , Arun Mohanty , Raja Ram Mantri %T A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation %D 2019 %J The European Research Journal %P -2149-3189 %V 5 %N 2 %R doi: 10.18621/eurj.397159 %U 10.18621/eurj.397159
ISNAD Agarwal, Deepak , Makhija, Aman , Mohanty, Arun , Mantri, Raja Ram . "A rare case of left ventricular lead stabilization utilizing a coronary stent placement during CRT-D implantation". The European Research Journal 5 / 2 (Mart 2019): 407-409. http://dx.doi.org/10.18621/eurj.397159